Vacuum Circuit Breakers – 12 kV

Get a Quote

Requirement:

Vacuum-Circuit-Breakers-VCB-12KV_header

VACUUM CIRCUIT BREAKERS 12KV 

  • – Cost effective breakers for Switchgear Panel Manufacturers

– Fully type tested at CPRI

– Ex-Stock Availability

– Compact breakers suitable for 600 mm width Switchgear panels

– Suitable for Floor – Type, cassette type & RMU type panels

– Suitable for retrofitting

– A Compact, Light, Weight construction, Optimized to give minimum weight to KA ratio.

– Superior mechanical endurance limit Maintenance required only after 10,000 operations.

– A Unique ‘U’ shaped insulation barrier housing for the Vaccum interrupters, imparting maximum mechanical strength against electrodynamic forces and provides most effective phase to phase and phase to earth segregation.

– A screw type racking arrangement for easy insertion and withdrawl of the Circuit Breaker renders perfect contact pressure, independent of operator’s force

– A simple motor charged spring operating mechanism noted for its high performance reliability.

– A versatile mechanism capable of operating Vacuum Interrupters of any type . Hence, dependence on single source of Vacuum interrputers eliminated.

– Trip free mechanism suitable for repeated auto reclosing duty.

– Spring Charging time of less than 10 seconds.

– Totally enclosed construction for spring charging motor.

– Easy visual check of contact erosion.

Type Motor & Manually Charged
Charging Time of motorised mechanism Less than 10 Sec
Coil voltage* 24/30/48/110/220 V DC
Trip/closed coil power 350 Watts
Motor operating voltage 230 V AC / DC
Power required by charging motor 80 Watts
Type of closing latch Designed to close & latch
Auxiliary switch Upto 8 NO + 8 NC
Mechanical Operating Counter 5 digit non resetting type
* Different voltages as per customer requirement
Generated by wpDataTables
TYPE ASIVB - 12
Operating Method Manual / Motor Spring ChargeType
Rated Voltage KV 12
No. of Poles Nos 3
Frequency Hz 50/60
Rated Current Amp 630 / 1250 / 2000
Short Circuit Current KA 13.1 / 20 /25
Making Current KAP 33 / 50 / 62.5
Duration of short time current Sec. 3
Insulation Level Impulse Power Frequency rms KVp KV 75/95 28
Contact travel mm 7 (+1, -1)
Opening Time Cycles Less than 2 cycles
Interrupting Time Cycles Less than 3 cycles
Closing Time Cycles Less than 3 cycles
Duty cycle Cycles 0-0.3 sec. -CO-3 min-CO
Applicable Standard IEC 62271-100, IS 13118
Generated by wpDataTables